The following steps will ensure a successful under tile heating installation :
Background PreparationThe floor must be in good condition, firm and sound, and must have a moisture content of 5% or less. The surface must be clean and dry and free from all traces of dust, debris, existing coatings or coverings, old fixatives, etc.
The surface where the under tile heating is to be installed must be primed prior to the heating elements being installed, as follows:
- Woodfloated (rough, porous) surfaces- prime with a coat of TAL FLOOR PRIMER.
- Powerfloated or steelfloated (smooth, dense) surfaces - prime with a slurry consisting of one part TAL FLOORKEY;mixed with two parts ordinary cement (by volume) which is applied by block brush.
The under-tile heating should be laid and pinned in place in accordance with
the manufacturer’s instructions once the priming coat is dry.
ScreedingAdd 20kg
TAL SUPERSCREED to 5 litres of
TAL SCREEDBINDER (replacing the water in the mix), and mix until a smooth, lump-free paste is obtained. Stir occasionally whilst in use. Do not mix up more than can be used in 20 –30 minutes.
Apply
TAL SUPERSCREED mixed with
TAL SCREEDBINDER over the elements, ensuring that all wires are completely covered. Work to a smooth, level surface. Allow 24 hours drying time before proceeding.
NOTE : If a separating covering mat is to be used, this must be placed in the wet screed over the heating elements. A further layer of
TAL SUPERSCREEDmixed with
TAL SCREEDBINDER at least 2mm thick must be applied over the mat, ensuring that the mat is totally saturated from both sides and forms part of the levelling compound. Allow 24 hours drying time before proceeding.
TILING
Tiles should be installed using a latex modified adhesive system, i.e.
TAL BONDshould be used as a total water replacement in the adhesive and grout mix. Tile panel movement joints should be created at maximum 3 meter centres in both directions, as well as around the perimeter of the floor.
NOTE : Allow the system to fully cure before switching the ceramic heaters on, i.e. wait at least 28 days.
Tile adhesives should not be used to cover under tile heating elements because :
- Tile adhesives do not have the same compressive strength as screeding compounds.
- Tile adhesives are far thicker than screeding compounds and will not be able to penetrate through the fibres in the mat.